Products designed for industrial applications.
General terms and conditions for sale are available on
www.camozzi.com.Series CSB and CSC proximity switches
CATALOGUE
1
/9.15.03
1
>
Release 8.7
MOVEMENT >
MOVEMENT
There is no protection on the Reed sensors on the inductive load,
therefore it is advisable to use electric circuits with protection
against the voltage spikes: the first for direct current (DC), the
second for alternating current (AC).
1 = Reed sensor
2 = Load
3 = Diode / Varistor
When the wire length of sensor connection load is more than
10m, inductors shall be installed in series near the sensor to
avoid ripple.
1 = Reed sensor
2 = Load
R = Resistor
C = Capacitor
Electric circuits with protection against voltage spikes
There is no protection on the Reed sensors on the inductive load,
therefore it is advisable to use electric circuits with protection
against the voltage spikes.
BN = Brown
BU = Blue
C = Load
When the wire length of sensor connection load is more than
10m, inductors shall be installed in series near the sensor to
avoid ripple.
BN = Brown
BU = Blue
C = Load
When L is more than 10mt. the cable has to be considered as an
inductive load.
Electric circuits with protection against voltage spikes