Series 3 and 4 mechanically operated sensor valves

CATALOGUE

2

/4.15.02

2

>

Release 8.7

CONTROL >

CONTROL

CODING EXAMPLE

3

SERIES:

3

4

3

FUNCTION:

3 = 3/2-way NC

4 = 3/2-way NO

5 = 5/2-way

8

PORTS:

8 = G1/8

4 = G1/4

D15

ACTUATION:

D15 = pressure drop/spring

015 = pressure/spring

011 = pressure/pressure

9A5

DEVICES:

9A5 = lever sensor, spring return

194 = plunger sensor, spring return

294 = plunger sensor, bistable

195 = lever/roller, spring return

295 = lever/roller, bistable

3 3

8

-

D15

-

9A5

Mod.

338-D15-9A5

Valve

Operating pressure = 4 ÷ 10 bar.

Flow rate = 700 Nl/min.

Actuating force at 6 bar = 2N

The function of the valve is indicated by the symbol

when operating between 4 and 10 bar.