Products designed for industrial applications.
General terms and conditions for sale are available on
www.camozzi.com.2
Series SCS, VNR, VSO, VSC and VMR automatic valves
CONTROL >
CATALOGUE
>
Release 8.7
/6.05.01
2
CONTROL
Series SCS, VNR, VSO, VSC and VMR
automatic valves
Circuit selector Mod. SCS
Series VNR unidirectional valves
Series VSO - VSC quick exhaust valves
Valve with adjustable exhaust Mod. VMR
Automatic valves are defined as those
valves which change their state simply
as a result of compressed air being
present or absent at their inlets.
The circuit selector Mod. SCS - 668-06
enables two signals coming alternately
from two different points to be
channelled towards the same point.
Series VNR unidirectional valves allow
operation at low pressures both when
there is a free flow and during retention.
Series VSC and VSO quick exhaust
valves are commonly used to increase
the speed of cylinders or for rapid
depressurisation of tanks containing
compressed air.
The adjustable valves Mod. VMR 1/8-
B10 allow to maintain tank/capacity at a
constant pressure value and thus enable
a quick exhaust in the atmosphere even
in case of an internal overpressure.
»
»
Mod. SCS: channelling of two
signals coming alternately
from two different points
towards the same point
»
»
Series VNR: operations
at low pressures
»
»
Series VSC - VSO:
able to increase the
speed of cylinders
»
»
Series VSC - VSO:
depressurisation of tanks
containing compressed air
»
»
Mod. VMR: able to maintain
pressure constant at a set
value which allows the
overpressure to exhaust
GENERAL DATA
Valve group
automatic valves
Construction
Mod. SCS, Series VNR, Series VSO and Series VSC: poppet-type
Mod. VMR: diaphragm type
Materials
Series SCS: AL body - brass bush - NBR seals - Delrin poppet
Series VNR: brass body - NBR seals - stainless steel spring
Series VSO: brass body - NBR seals
Series VSC: brass body - Desmopan seal
Mod. VMR: brass body - zinc-plated steel spring - NBR seals
Mounting
in any position
Ports
according to the different models (see tables)
Operating temperature Mod. SCS, Series VNR, Series VSO and Series VSC: 0°C ÷ 80°C (with dry air -20°C)
Mod. VMR: -5°C ÷ 50°C (with the dew point of the fluid lower than 2°C at the min. working temperature)
Fluid
filtered air, without lubrication. If lubricated air is used, it is recommended to use ISO VG32 oil. Once applied the lubrication should
never be interrupted.