Background Image
Table of Contents Table of Contents
Previous Page  751 / 1144 Next Page
Information
Show Menu
Previous Page 751 / 1144 Next Page
Page Background

Products designed for industrial applications.

General terms and conditions for sale are available on

www.camozzi.com.

Series AP proportional valves

CATALOGUE

2

/15.01.01

2

>

Release 8.7

CONTROL >

CONTROL

Series AP

directly operated proportional valves

2/2-way proportional valves, NC

Sizes: 16 - 22 mm

Series AP directly operated 2/2-way

proportional solenoid valves, NC, with

nominal diameters range from 0.8 to

2.4 mm, can be used where an open

loop flow control is required, with gas

mixtures, to control free flows or blows,

or emptying chambers using vacuum.

Series AP proportional valves have been

manufactured to optimize and reduce

friction and stick-slip effects.

The output flow is proportional to the

control signal.

As they can work also in vacuum,

a minimum working pressure is not

required.

»

»

Available in two sizes:

16 and 22 mm

»

»

PWM or current operation

»

»

Open loop flow control

»

»

Also suitable for use

with vacuum

»

»

Size 16mm also available

with body in PVDF

GENERAL DATA

Function

Operation

Ports

Nominal diameter (ø)

Nominal flow (Qn - Kv)

Maximum operating pressure

Hysteresis

Repeatibility

Operating temperature

Medium

Installation

2/2 NC

proportional directly operated

M5 - G1/8

see table

see table

see table

16 mm size < 7% 22 mm size < 5%

16 mm size < 5% 22 mm size < 3%

0 ÷ 60°C

filtered compressed air, unlubricated, according to ISO 8573-1 class 3.4.3, inert gas

in any position

Materials

body = brass / PVDF (for size 16mm only)

seals = NBR

Nominal resistance

Rated current

GP7 GPH U711 U712

193 ohm 48 ohm 85 ohm 22 ohm

125 mA 250 mA 271 mA 0.542 mA

While choosing the valve characteristics and in order to reach the highest performances, it is important to know that there must be a pressure difference of

90% at least between the inlet and the outlet. For example: inlet P 10 bar - outlet P max 1 bar up to free flow.