Produits pour utilisation industrielle avec air comprimé exclusivement.
Pour tout autre environnement ou fluide, nous consulter.
Conditions générales de vente et de garantie disponibles sur
www.camozzi.com.2
Ilots de distribution Série 3 Plug-In
CONTROLE >
CATALOGUE
>
Version 8.7
/3.05.03
2
CONTROLE
La lettre indique
le nbre de distributeurs
Nbre de postes,
avec constitution des modules
formant l’îlot
Position du
connecteur SUB-D
et nombre de distributeurs
connectés ( gauche )
Position
du connecteur SUB-D
et nombre de distributeurs
connectés ( droite )
Codification de
la configuration /
nbre de postes
Codification de
la configuration
A = 2 pos.
[2]
(2)
-
2
2
-
A
A
A - A
A - B
B = 3 pos.
[3]
(3)
-
3
3
-
B
B
A - A
A - B
C = 4 pos.
[2] [2]
(2) (2)
-
4
4
-
C
C
A - A
A - B
D = 5 pos.
[3] [2]
(3) (2)
[2] [3]
(2) (3)
-
5
-
5
5
-
5
-
D
D
D
D
A - A
A - B
A - C
A - D
E = 6 pos.
[3] [3]
(3) (3)
[2] [2] [2]
(2) (2) (2)
-
6
-
6
6
-
6
-
E
E
E
E
A - A
A - B
B - A
B - B
F = 7 pos.
[2] [3] [2]
(2)(3)(2)
[2] [2] [3]
(2) (2) (3)
[3] [2] [2]
(3) (2) (2)
-
7
-
7
-
7
7
-
7
-
7
-
F
F
F
F
F
F
A - A
A - B
B - A
B - B
B - C
B - D
G = 8 pos.
[3] [3] [2]
(3)(3)(2)
[2] [3] [3]
(2)(3)(3)
[2] [2] [2] [2]
(2)(2)(2) (2)
[3] [2] [3]
(3) (2) (3)
-
8
-
8
-
8
-
8
8
-
8
-
8
-
8
-
G
G
G
G
G
G
G
G
A - A
A - B
A - C
A - D
B - A
B - B
B - C
B - D
H = 9 pos.
[3] [3] [3]
(3)(3)(3)
[3] [2] [2] [2]
(3)(2)(2) (2)
[2] [3] [2] [2]
(2) (3) (2) (2)
[2] [2] [3] [2]
(2) (2) (3) (2)
[2] [2] [2] [3]
(2) (2) (2) (3)
-
9
-
9
-
9
-
9
-
9
9
-
9
-
9
-
9
-
9
-
H
H
H
H
H
H
H
H
H
H
A - A
A - B
B - A
B - B
B - C
B - D
B - E
B - F
B - G
B - H
I = 10 pos.
[2] [3] [3] [2]
(2)(3)(3)(2)
-
10
10
-
I
I
A - A
A - B
J = 11 pos.
[2] [3] [3] [3]
(2)(3)(3)(3)
[3] [3] [3] [2]
(3)(3)(3)(2)
-
11
-
11
11
-
11
-
J
J
J
J
A - A
A - B
A - C
A - D
K = 12 pos.
(3) [3] [3] [3]
(3)(3)[3] [3]
(3) (3)(3) [3]
3
6
9
9
6
3
K
K
K
A - A
A - B
A - C
L = 13 pos.
(2) [3] [3] [3] [2]
(2) (3) [3] [3] [2]
(2) (3) (3) [3] [2]
(2) (3) (3)(3) [2]
2
5
8
11
11
8
5
2
L
L
L
L
A - A
A - B
A - C
A - D
M = 14 pos.
(2) (3) [3] [3] [3]
(2) (3) (3) [3] [3]
(2) (3) (3) (3) [3]
(3) [3] [3] [3] [2]
(3) (3) [3] [3] [2]
(3) (3) (3) [3] [2]
5
8
11
3
6
9
9
6
3
11
8
5
M
M
M
M
M
M
A - A
A - B
A - C
A - D
A - E
A - F
N = 15 pos.
(3) (3) [3] [3] [3]
(3) (3) (3) [3] [3]
6
9
9
6
N
N
A - A
A - B
O = 16 pos.
(2) (3) [3] [3] [3] [2]
(2) (3) (3) [3] [3] [2]
(2) (3) (3) (3) [3] [2]
5
8
11
11
8
5
O
O
O
A - A
A - B
A - C
P = 17 pos.
(2) (3) (3) [3] [3] [3]
(2) (3) (3) (3) [3] [3]
(3) (3) [3] [3] [3] [2]
(3) (3) (3) [3] [3] [2]
8
11
6
9
9
6
11
8
P
P
P
P
A - A
A - B
A - C
A - D
Q = 18 pos.
(3) (3) (3) [3] [3] [3]
9
9
Q
A - A
R = 19 pos.
(2) (3) (3) [3] [3] [3] [2]
(2) (3) (3) (3) [3] [3] [2]
8
11
11
8
R
R
A - A
A - B
S = 20 pos.
(2) (3) (3) (3) [3] [3] [3]
(3) (3) (3) [3] [3] [3] [2]
11
9
9
11
S
S
A - A
A - B
T = 21 pos.*
(3) (3) [3] [3] [3] [3] [3]
(3) (3) (3) [3] [3] [3] [3]
10
11
11
10
T
T
A - A
A - B
U = 22 pos.
(2) (3) (3) (3) [3] [3] [3] [2]
11
11
U
A - A
* le module électrique ne corresponde pas à quel pneumatique.
Dans la référence, la position des distributeurs est toujours de gauche à droite. La position de la partie électrique de l’îlot se trouve
au-dessus de la partie pneumatique comme montré sur la photo page 2.3.05.01. La configuration des modules permet l’insertion
d’un obturateur Mod. CNVL-TP pour la création d’une zone de pression supplémentaire.
TABLEAU POUR CONFIGURATION DES ILOTS SERIE 3 PLUG-IN