Products designed for industrial applications.

General terms and conditions for sale are available on

www.camozzi.com.

Series MD activated carbon filters

CATALOGUE

3

/3.15.01

3

>

Release 8.8

TREATMENT >

TREATMENT

Series MD

activated carbon filters

Ports with interchangeable cartridges: threaded (1/8, 1/4, 3/8) or

integrated with super-rapid fitting for tube with Ø 6, 8 and 10 mm

Modular assembly

Bowl with technopolymer cover and bayonet-type mounting

Within a battery of filters the activated

carbon version is placed at the end

because it requires a pre-filtering like the

coalescing filter.

Given the characteristic of this filter, it

is recommended to replace the filter

element at least every 6 months or 1000

working hours.

The operating principle is based on the

adsorption characteristic of the filtering

element which is composed of extremely

porous fibers placed on different layers.

These fibers create a cross-linked and

are thus able to adsorb wet parts and

contaminants remaining in the passing

air, for example oil vapours/smokes, as

well as odours generated from these

contaminants.

»

»

Removal of oil, liquid and

gas components from

compressed air through

the active carbons

»

»

Air quality in compliance

with ISO 8573-1

standard, Class 1.7.1

»

»

Visual blockage indicator

»

»

Bowl locking system reducing

the risk of accidents

»

»

Additional air intakes with

the same characteristics

of the inlet air (line)

GENERAL DATA

Construction

modular, compact with activated carbon filtering element

Materials

see TABLE OF MATERIALS (pag. 3/0.15.02)

Ports

With interchangeable cartridges: 1/8, 1/4 and 3/8 threaded or integrated with super-rapid fitting for

tube with Ø 6, 8 and 10 mm

Mounting

vertical in-line;

wall-mounting by means of through holes in the body or with a support bracket

Operating temperature

10°C ÷ 40°C (t max = 60°C)

Condensate drain

not present

Quality of delivered air according to ISO 8573-1 2010 Class 1.7.1 (pre-filtering in Class 1.8.1 is recommended)

Operating pressure

0.3 ÷ 16 bar

Nominal flow

see FLOW DIAGRAMS on the following pages

Filtering element

active carbon

Residual oil content

< 0.003 mg/m³

Fluid

compressed air