Background Image
Table of Contents Table of Contents
Previous Page  1043 / 1278 Next Page
Information
Show Menu
Previous Page 1043 / 1278 Next Page
Page Background

Products designed for industrial applications.

General terms and conditions for sale are available on

www.camozzi.com.

3

Series N pressure regulators

TREATMENT >

CATALOGUE

>

Release 8.8

/4.10.02

3

TREATMENT

CODING EXAMPLE

N

SERIES

12

SIZE:

12

04

PORTS:

08 = G1/8

04 = G1/4

R

R = REGULATOR

T

OPERATING PRESSURE:

0 = 0.5 ÷ 10 bar (standard)

1 = 0 ÷ 4 bar

2 = 0 ÷ 2 bar

7 = 0.5 ÷ 7 bar

T = calibrated *

B = locked *

0

DESIGN TYPE:

0 = self-relieving

1 = non-relieving

* NOTE: IF THE REGULATOR IS CALIBRATED OR LOCKED, AFTER THE DESIGN TYPE ADD THE INLET PRESSURE “■” AND THE OUTLET PRESSURE “●”

INLET PRESSURE:

■ = enter the SUPPLY pressure value

OUTLET PRESSURE:

● = enter the OUTLET pressure value for the LOCKED regulator or

the maximum value of the ADJUSTABLE pressure for the CALIBRATED regulator

Example of a calibrated regulator with Inlet Pressure = 6.3 bar and Outlet Pressure = 4.5 bar

Complete part number: N1204-RT0-6.3-4.5

N 12 04 -

R T 0 -

-

DIMENSIONS

Mod.

A

B

C

F

G

I

L

M

N

R

S

U

N1208-R00

92

53

39

26

27

28

30X1,5

45

45

3

0÷6

G1/8

N1204-R00

92

53

39

26

27

28

30X1,5

45

45

3

0÷6

G1/4

Pressure regulators Series N

Calibrated or blocked regulators on request

PR01 = regulator without relieving