Products designed for industrial applications.
General terms and conditions for sale are available on
www.camozzi.com.3
Series M pressure microregulators
TREATMENT >
CATALOGUE
>
Release 8.8
/5.05.02
3
TREATMENT
CODING EXAMPLE
M
SERIES
0
SIZE
04
PORTS:
08 = G1/8
04 = G1/4
R
REGULATOR
T
OPERATING PRESSURE:
0 = 0.5 ÷ 10 bar (standard)
1 = 0 ÷ 4 bar
2 = 0 ÷ 2 bar
7 = 0.5 ÷ 7 bar
T = calibrated *
B = locked *
0
DESIGN TYPE:
0 = self relieving
1 = non relieving
5 = precise setting
REGULATION TYPE:
= without high relief flow (standard)
VS = high relief flow
* NOTE: IF THE REGULATOR IS CALIBRATED OR LOCKED, AFTER THE REGULATION TYPE ADD THE INLET PRESSURE “■” AND THE OUTLET PRESSURE “●”
INLET PRESSURE:
■ = enter the SUPPLY pressure value
OUTLET PRESSURE:
● = enter the OUTLET pressure value for the LOCKED regulator or
the maximum value of the ADJUSTABLE pressure for the CALIBRATED regulator
Example of a calibrated regulator with Inlet Pressure = 6.3 bar and Outlet Pressure = 4.5 bar
Complete part number: M04-RT0-6.3-4.5
M 0
04
-
R T 0 -
■ -
●
6512
FLOW DIAGRAMS
Flow diagram for models: M004-R00
Pa = Inlet pressure
Pr = Regulated pressure
Qn = Flow
Flow diagram for models: M008-R00
Pa = Inlet pressure
Pr = Regulated pressure
Qn = Flow