Products designed for industrial applications.
General terms and conditions for sale are available on
www.camozzi.com.3
Series PG digital pressure gauges
TREATMENT >
CATALOGUE
>
Release 8.8
/6.06.02
3
TREATMENT
CHARACTERISTICS
Vacuum Pressure
PG...-VB... PG...-PB...
Pressure units
psi, bar, mmHg, kPa psi, bar, kgf/cm², MPa
programmable by the user programmable by the user
Rated pressure range
0 ÷ -1 bar 0 ÷ 10 bar
Display pressure range
0.1 ÷ -1 bar -0.1 ÷ 10 bar
Withstand pressure
3 bar 15 bar
Repeatability
≤ ± 1% F.S. ± 1 digit ≤ ± 0,2% F.S. ± 1 digit
Resolution: kPa
MPa
kgf/cm²
bar
psi
1 -
- 0.001
0.01 0.01
0.01 0.01
0.1 0.1
Indicator accuracy
≤ ± 2% F.S. ± 1 digit (ambient temperature: 25 ± 3°C)
Medium
Filtered air, incombustible and non-corrosive gases
Back light
Yes
Sample rate
2 Hz (2 times/second)
LCD display
3 ½ digit, 7 segment
Environment: Protection class
Temperature
Relative humidity
Vibrations
Shock
IP65 (an air tube must be installed to maintain this grade)
Operation: 0 ÷ 50°C
Storage: -10 ÷ 60°C
(no condensation or freezing)
Operation/storage: 35 ÷ 85% RH
(no condensation)
Total amplitude 1.5mm or 10G
10Hz-55Hz-10Hz scan for 1 minute
2 hours for each direction of X, Y and Z
100 m/s² (10G)
3 times for each direction of X, Y and Z
Changes due to temperature
≤ ± 2% F.S. of detected pressure (25°C) within the operating temperature range
Pneumatic connections ports
G1/4 - M5 or G1/8 - M5
FOR BATTERY-POWERED PRESSURE GAUGES ONLY
Battery: Type
Life
Low-power indicator
Replacement
Turn-on interval
CR 2032 lithium
1 year (5 times/day)
Yes
Yes
Display turns off after 60 seconds
FOR PRESSURE GAUGES WITH POWER SUPPLY CABLE ONLY
Supply voltage
Power consumption
Maximum voltage
Isolation resistance
from 12 to 28 V DC±10% Ripple
10 mA
1000V AC in 1-min (between the casing and the cables)
50 Mohm min (at 500 V DC, between the casing and the cables)
Electrical connection: for pressure gauges PG…-2
for pressure gauges PG…-M
Unshielded 2-pole cable, length 2 m
Connection with M8 4-pole connector
TECHNICAL DATA