Series CST-CSV-CSH-CSB-CSC-CSD sensors

MOVEMENT >

CATALOGUE

>

Release 8.8

/9.05.04

1

MOVEMENT

Magnetic proximity switches with 2- or 3-wire cable for T-slot

Note for Mod. CST-220, CST-220-5:

in case of polarity reversing the sensor will still be operating, but the LED diode won’t turn on.

Mod.

Operation Connections

Voltage

Output Max. current

Max Load

Protection

L = length cable

CST-220

Reed

2 wires 10 ÷ 110 V AC/DC-230 V AC -

250 mA 10 VA / 8W

None

2 m

CST-220-5

Reed

2 wires 10 ÷ 110 V AC/DC-230 V AC -

250 mA 10 VA / 8 W

None

5 m

CST-232

Reed

3 wires

5 ÷ 30 V AC/DC

PNP 250 mA 10 VA / 8 W

Against polarity reversing

2 m

CST-232-5

Reed

3 wires

5 ÷ 30 V AC/DC

PNP 250 mA 10 VA / 8 W

Against polarity reversing

5 m

CST-332 Magnetoresistive 3 wires

10 ÷ 27 V DC

PNP 100 mA

6 W Against polarity reversing and overvoltage

2 m

CST-332-5 Magnetoresistive 3 wires

10 ÷ 27 V DC

PNP 100 mA

6 W Against polarity reversing and overvoltage

5 m

CST-532

Hall effect

3 wires

10 ÷ 27 V DC

PNP 100 mA

6 W Against polarity reversing and overvoltage

2 m

CST-532-5

Hall effect

3 wires

10 ÷ 27 V DC

PNP 100 mA

6 W Against polarity reversing and overvoltage

5 m

Magnetic proximity switches with 2- or 3-wire cable for V-slot

Note for Mod. CSV-220:

In case of polarity reversing the sensor will still be operating, but the LED diode won’t turn on.

Mod.

Operation

Connections

Voltage

Output Max. current

Max Load

Protection

L = length cable

CSV-220

Reed

2 wires 10 ÷ 110 V AC/DC-230 V AC -

250 mA 10 VA / 8 W

None

2 m

CSV-232

Reed

3 wires

5 ÷ 30 V AC/DC

PNP 250 mA 10 VA / 8W

Against polarity reversing

2 m

CSV-332 Magnetoresistive 3 wires

10 ÷ 27 V DC

PNP 100 mA

6 W Against polarity reversing and overvoltage

2 m