Background Image
Table of Contents Table of Contents
Previous Page  483 / 1278 Next Page
Information
Show Menu
Previous Page 483 / 1278 Next Page
Page Background

Products designed for industrial applications.

General terms and conditions for sale are available on

www.camozzi.com.

2

Series 8 pneumatically and electropneumatically operated valves

CONTROL >

CATALOGUE

>

Release 8.8

/2.04.02

2

CONTROL

CODING EXAMPLE

8 10 C3 4 04 - F1 3 1 Y - N 00 2C C015

8

SERIES

10

SIZE:

10 = Size 1

20 = Size 2

30 = Size 3

C3

TYPE OF BODY:

C3 = threaded body

4

NUMBER OF WAYS - FUNCTIONS:

1 = 2/2-way NC

2 = 2/2-way NO

4 = 3/2-way NC

5 = 3/2-way NO

04

PNEUMATIC CONNECTIONS:

04 = G1/8 (Size 1)

05 = G1/4 (Size 2)

06 = G3/8 (Size 3)

F1

NOMINAL DIAMETER:

F1 = 5.0 mm (Size 1)

G7 = 6.6 mm (Size 2)

K1 = 9.0 mm (Size 3)

3

SEAL MATERIAL:

3 = FKM

1

BODY MATERIAL:

1 = aluminium

Y

MANUAL OVERRIDE:

N = not provided

Y = provided monostable

N

MOUNTING ACCESSORIES:

N = not provided

00

OPTIONS:

00 = no option

PP = pneumatic piloting

PE = electropilot with external piloting

2C

ELECTRICAL CONNECTION:

2C = connection type KN 90° + protection + led (Size 1)

2F = connection type KN 90° in line + protection + led (Size 1)

3A = connection DIN EN 175 301-803-C (8 mm)

4A = industry standard connection (9.4 mm)

7A = wires - length 300 mm (Size 2 - 3)

C015

VOLTAGE - POWER CONSUMPTION:

C012 = 12V DC 1.3/0.25W (Size 1)

C014 = 24V DC 1.3/0.25W (Size 1)

C020 = 12V DC 2W (Size 2 - 3)

C023 = 24V DC 2W (Size 2 - 3)

C025 = 48V DC 2W (Size 2 - 3)

VERSION:

= standard

OX1 = for use with oxygen (non volatile residual less than 550 mg/m²)

OX2 = for use with oxygen (non volatile residual less than 33 mg/m²)