Background Image
Table of Contents Table of Contents
Previous Page  693 / 1278 Next Page
Information
Show Menu
Previous Page 693 / 1278 Next Page
Page Background

Products designed for industrial applications.

General terms and conditions for sale are available on

www.camozzi.com.

2

Series HN valve islands

CONTROL >

CATALOGUE

>

Release 8.8

/3.40.30

2

CONTROL

CODING EXAMPLE OF SUBBASES - Accessories

H

SERIES

A

TYPE:

A = accessories

1

SIZE:

0 = for X-Y-K-T-U-V-Z

1 = 10.5

2 = 21

S

TYPE OF ACCESSORY:

R = subbase for multipole connection

G = seal

W = subbase without electronic board

(option valid only for position 2a.

See the components list on page 2/3.40.08 - Multipole version -

and 2/3.40.09 - Fieldbus version)

A

SUBBASE:

A = through - M7 threads

AZ = through - M7 threads, monostable

D = channel 1, 3, 5 closed - M7 threads

DZ = channel 1, 3, 5 closed - M7 threads, monostable

G = channel 3, 5 closed - M7 threads

GZ = channel 3, 5 closed - M7 threads, monostable

Q = through - G1/8 threads

X = supplementary supply and exhaust

Y = supplementary supply and exhaust with integrated silencer

W = supply from the exhausts

K = separation of electrical supply and supplementary pneumatic supply

SEAL:

T = diaphragm seal for the closure of channels 1, 3, 5

U = diaphragm seal for the closure of channel 1

V = diaphragm seal for the closure of channels 3, 5

P = through

Detailed descriptions of the available accessories can be found in the components list on page 2/3.40.08 (Multipole version) e 2/3.40.09 (Fieldbus version)

NOTE: subbases are always supplied without connection fittings.

H A

1

R

-

A