Products designed for industrial applications.
General terms and conditions for sale are available on
www.camozzi.com.2
Series SCU, MCU, SVU, MVU, SCO, MCO valves
CONTROL >
CATALOGUE
>
Release 8.8
/7.05.02
2
CONTROL
CODING EXAMPLE
M
ACTUATION:
M = Manual
S = Screwdriver
CU
ASSEMBLY:
CU = on cylinders unidirectional
VU = on valves unidirectional
CO = bidirectional
7
VERSIONS:
6 = needle (screwdriver operated)
7 = needle (manual operated)
02
NOMINAL DIAMETER:
02 = ø 1,5 max
04 = ø 2 max
06 = ø 4 max
08 = ø 7 max
10 = ø 12 max
M5
PORTS:
M5 = M5
1/8 = G1/8
1/4 = G1/4
3/8 = G3/8
1/2 = G1/2
To ensure the right choice of unidirectional flow controller, proceed as follows: calculate the quantity of air in Nl/min (see cylinder Table); determine the stroke time of the cylinder;
refer to graph to see which controller is the right type.
M CU
7
02
-
M5
6512
UNIDIRECTIONAL AND BIDIRECTIONAL FLOW CONTROLLERS
IDENTIFICATION OF DIFFERENT TYPES:
SCU - MCU = assembly directly on the cylinders
SVU - MVU = assembly directly on the valves
SCO - MCO = assembly directly on the cylinders or valves
Flow Qn (Nl/min.) from 2 → 1 with controller OPEN: 70
Flow Qn (Nl/min.) from 2 → 1 with controller CLOSED: 33
Qn = supply pressure of 6 bar and with ΔP = 1 bar at the outlet
N° = number of screw turns.