Products designed for industrial applications.
General terms and conditions for sale are available on
www.camozzi.com.Series ER200 digital electro-pneumatic regulators
CATALOGUE
2
/15.51.03
2
>
Release 8.8
CONTROL >
CONTROL
Model
ER204-9 0/1/2 X
ER238-9 0/1/2 X
Analog type
ER238-9P X
ER238-9P X
Parallel type
Fluid
Cleaned air
Cleaned air
Max. working pressure
10 bar
10 bar
Min. working pressure
Control pressure +
max. control pressure + 1 bar
Control pressure +
max. control pressure + 1 bar
Pressure control range
0,5 - 9 bar
0,5 - 9 bar
Class protection
IP40
IP40
Power supply voltage
DC24V ± 10%
(stabilized power supply
with a ripple rate of 1% or less)
DC24V ± 10%
(stabilized power supply
with a ripple rate of 1% or less )
Consumption current
0.15 A
(rush corrent 0.6 A or less)
0.15 A
(rush corrent 0.6 A or less)
Input signal
( Input impedance )
0 to 10 VDC (6.7kΩ)
0 to 5 VDC (10kΩ)
4 to 20 mADC (250Ω)
10 bit
Preset input
8 points
N/A
Output signal
Analog output 1-5 VDC
(load to be connected impedance 500 kΩ)
Switch output NPN or PNP, open collector,
30 V, 50 mA, voltage drop 2.4 V,
compatible for usage in PLC and Relay
Analog output 1-5 VDC
(load to be connected impedance 500 kΩ)
Switch output NPN or PNP, open collector,
30 V, 50 mA, voltage drop 2.4 V,
compatible for usage in PLC and Relay
Error output signal
NPN or PNP, open collector,
30 V, 50 mA, voltage drop 2.4 V,
compatible for usage in PLC and Relay
NPN or PNP, open collector,
30 V, 50 mA, voltage drop 2.4 V,
compatible for usage in PLC and Relay
Direct memory setting
0,05 - 9 bar - min. input 0,01 bar
max. error 0,02 bar
0,05 - 9 bar - min. input 0,01 bar
max. error 0,02 bar
Hysteresis
Note 2
0.5% F.S. or less
0.5% F.S. or less
Linearity
Note 2
±0.3% F.S. or less
±0.3% F.S. or less
Resolution
Note 2
0.2% F.S. or less
0.2% F.S. or less
Repeatability
Note 2
0.3% F.S. or less
0.3% F.S. or less
Temperature characteristics:
Zero point fluctuation
0.15% F.S./°C or less
0.15% F.S./°C or less
Temperature characteristics:
Span point fluctuation
0.07% F.S./°C or less
0.07% F.S./°C or less
Max. flow rate(ANR)
Note 3
1500 l/min
1500 l/min
Step response time
No load
0.2 sec. or less
0.2 sec. or less
Step response time
Load 1000 cm³
0.8 sec. or less
0.8 sec. or less
Mechanical vibration proof
98 m/s²
98 m/s²
Ambient temperature
5 to 50 °C
5 to 50 °C
Fluid temperature
5 to 50 °C
5 to 50 °C
Connecting port size
IN/OUT
G1/4 - G3/8
G1/4 - G3/8
Connecting port size
EXHAUST
G3/8
G3/8
Mounting
Free
Free
Weight
450g
450g
Note 1:
Select either analog or switch output
Note 2:
This characteristic is guaranteed within a regulation range between 10 and 90% of the full scale, with
a power voltage of 24V±10%, a supply pressure of 1 bar higher compared with the set pressure (ex.
regulation of 3 bar, supply pressure of 3+1 = 4 bar) and a volume connected to the outlet without any loss.
In applications with great air consumption, such as the blowing, the indicated tolerance may change.
Note 3:
The above apply when working pressure
and control pressure are maximum.
Note 4:
The above apply when working pressure is maximum
and the step is as follows:
50% F.S. -> 100% F.S.
50% F.S. -> 60% F.S.
50% F.S. -> 40% F.S.
GENERAL DATA ER2XX-9XXX