Products designed for industrial applications.
General terms and conditions for sale are available on
www.camozzi.com.Series MX filter-regulators
CATALOGUE
3
/1.30.01
3
>
Release 8.8
TREATMENT >
TREATMENT
Series MX
filter-regulators
MX2 ports: G3/8, G1/2, G3/4 - MX3 ports: G3/4, G1
Modular
Bowl with technopolymer cover and bayonet-type mounting
Series MX filter-regulators integrate filter and pressure reducer in one unit. They are,
therefore, compact and suitable for pre-filtering functions.
Available with or without draining (relieving), they are equipped with a valve diaphragm
for a direct pressure regulation and with an integrated condensate drainer, manual or
automatic. Moreover, they are equipped with a built-in pressure gauge.
The Series MX has been realized to offer
a multi-sector solution that guarantees
saving in terms of installation time, space
and costs. A special configurator, available
on Camozzi website at
http://catalogue.camozzi.com (sec. Configurators), allows
the customer to choose the most suitable
solution for his application, selecting single
components or by configuring assembled
FRLs.
»
»
Filtering between
25 µm or 5 µm
»
»
Available versions:
with built-in gauge or
with ports for gauge
»
»
Lockable knob with closure
»
»
Bowl locking system reducing
the risk of accidents
GENERAL DATA
Construction
modular, compact with filtering element in HDPE
Materials
see TABLE OF MATERIALS (pag. 3/1.30.02)
Ports
MX2: G3/8 - G1/2 - G3/4
MX3: G3/4 - G1
Condensate capacity
MX2: 55 cc
MX3: 85 cc
Mounting
vertical in-line
wall-mounting (by means of clamps)
panel mounting
Operating temperature -5°C ÷ 50°C up to 16 bar (with the dew point of the fluid lower than 2°C at the min. working temperature)
-5°C ÷ 60°C up to 10 bar (with the dew point of the fluid lower than 2°C at the min. working temperature)
Porosity of filtering element 25 μm (standard)
5 μm
Draining of condensate MX2: manual-semi automatic (standard), automatic, depressurization protected, without drain with port G1/8
MX3: manual-semi automatic (standard), without drain with port G1/8
Operating pressure
0,3 ÷ 16 bar ((with automatic drain 1,5 ÷ 12)
Nominal flow
see FLOW DIAGRAMS (pag. 3/1.30.03)
Fluid
compressed air
Pressure gauge
version with built-in pressure gauge (standard)
version with G1/4 ports for pressure gauge (MX3 only)