Series MX soft start valves

TREATMENT >

CATALOGUE

>

Release 8.8

/1.40.03

3

TREATMENT

Pressurisation times as to the number of turns of the regulation

screw, with downstream volume of 5 litres. A = 5 turns - B =

4 turns - C = 3 turns - D = 2 turns - E = 1 turn. K = number of

turns of the regulation screw required to obtain the required

pressurisation time with an inlet pressure of 6 bar. Variations of

the inlet pressure can cause deviations of the pressure time by

± 20%. K = t/V where: V = volume of the downstream system in

litres; t = desired pressuring time in seconds.

EXAMPLE:

V = 5 litres

t = 16 seconds

K = 16/5 = 3,2

Using in the graph this value K, the number of turns of the

regulation screw will be approx. 0,8.

MX2 DIAGRAMS FOR PRESSURISATION TIMES

Pressurisation times as to the number of turns of the regulation

screw, with downstream volume of 5 litres. A = 5 turns - B =

4 turns - C = 3 turns - D = 2 turns - E = 1 turn. K = number of

turns of the regulation screw required to obtain the required

pressurisation time with an inlet pressure of 6 bar. Variations of

the inlet pressure can cause deviations of the pressure time by

± 20%. K = t/V where: V = volume of the downstream system in

litres; t = desired pressuring time in seconds.

EXAMPLE:

V = 5 litres

t = 16 seconds

K = 16/5 = 3,2

Using in the graph this value K, the number of turns of the

regulation screw will be approx. 1,8.

MX3 DIAGRAMS FOR PRESSURISATION TIMES