Products designed for industrial applications.
General terms and conditions for sale are available on
www.camozzi.com.3
Series MX soft start valves
TREATMENT >
CATALOGUE
>
Release 8.8
/1.40.03
3
TREATMENT
Pressurisation times as to the number of turns of the regulation
screw, with downstream volume of 5 litres. A = 5 turns - B =
4 turns - C = 3 turns - D = 2 turns - E = 1 turn. K = number of
turns of the regulation screw required to obtain the required
pressurisation time with an inlet pressure of 6 bar. Variations of
the inlet pressure can cause deviations of the pressure time by
± 20%. K = t/V where: V = volume of the downstream system in
litres; t = desired pressuring time in seconds.
EXAMPLE:
V = 5 litres
t = 16 seconds
K = 16/5 = 3,2
Using in the graph this value K, the number of turns of the
regulation screw will be approx. 0,8.
MX2 DIAGRAMS FOR PRESSURISATION TIMES
Pressurisation times as to the number of turns of the regulation
screw, with downstream volume of 5 litres. A = 5 turns - B =
4 turns - C = 3 turns - D = 2 turns - E = 1 turn. K = number of
turns of the regulation screw required to obtain the required
pressurisation time with an inlet pressure of 6 bar. Variations of
the inlet pressure can cause deviations of the pressure time by
± 20%. K = t/V where: V = volume of the downstream system in
litres; t = desired pressuring time in seconds.
EXAMPLE:
V = 5 litres
t = 16 seconds
K = 16/5 = 3,2
Using in the graph this value K, the number of turns of the
regulation screw will be approx. 1,8.
MX3 DIAGRAMS FOR PRESSURISATION TIMES