Background Image
Table of Contents Table of Contents
Previous Page  941 / 1278 Next Page
Information
Show Menu
Previous Page 941 / 1278 Next Page
Page Background

Products designed for industrial applications.

General terms and conditions for sale are available on

www.camozzi.com.

3

Series MX assembled FRL

TREATMENT >

CATALOGUE

>

Release 8.8

/1.50.03

3

TREATMENT

MX

SERIES

2

( 1 )

SIZE:

2 = G3/8 - G1/2 - G3/4

3 = G3/4 - G1

-

3/8

( 2 )

IN / OUT THREADS:

3/8 = G3/8

1/2 = G1/2

3/4 = G3/4

1 = G1

-

V01

( 3 )

[ * ]

MODULE + [ * ] (to configure the modules, see the single components pages):

F... = Filter

FC... = Coalescing filter

FCA... = Activated carbons filter

R... = Pressure regulator

L... = Lubricator

FR... = Filter-Regulator

V... = Lockable isolation valve

AV... = Soft start valve

B... = Take-off block (MX2: G1/2 only - MX3: G1 only)

The following ACCESSORIES can be added after every single module:

REGULATOR AND FILTER-REGULATOR MX2

+A56 = M053-P06 (Pressure gauge)

+A57 = M053-P10 (Pressure gauge)

+A58 = M063-P12 (Pressure gauge)

LOCKABLE ISOLATION VALVE MX2

+A30 = 2901 1/2’’ (Silencier)

+A31 = 2921 1/2’’ (Silencier)

+A32 = 2931 1/2’’ (Silencier)

+A33 = 2938 1/2’’ (Silencier)

SOFT START VALVE

+A00 = PM11-NA (Pressure switch, normally open)

+A01 = PM11-NC (Pressure switch, normally closed)

TAKE-OFF BLOCK MX2

+A08 = PM11-NA (normally open pressure switch)

with fitting for fixing to the module

+A09 = PM11-NC (normally closed pressure switch)

with fitting for fixing to the module

+A03 = PM11-SC with fitting for fixing to the module

Example: MX2-3/8-V01+A32XF00-KK-LH

REGULATOR AND FILTER-REGULATOR MX3

+A60 = M063-P06 (Pressure gauge)

+A61 = M063-P12 (Pressure gauge)

LOCKABLE ISOLATION VALVE MX3

+A34 = 2901 3/4’’ (Silencier)

+A35 = 2921 3/4’’ (Silencier)

+A36 = 2931 3/4’’ (Silencier)

TAKE-OFF BLOCK MX3

+A06 = PM11-NA (normally open pressure switch)

with fitting for fixing to the module

+A07 = PM11-NC (normally closed pressure switch)

with fitting for fixing to the module

+A02 = PM11-SC with fitting for fixing to the module

Example: MX3-3/4-V01+A36XF00-KK-LH

X

( 4 )

MODULES CONNECTION

(according to the positioning scheme on p. 3/1.50.04):

X = Rapid clamp kit

Z = Rapid clamp kit with wall fixing screw

Y = Rapid clamp kit with wall fixing brackets

F00

( 5 ) + [ * ]

see MODULE (3)

-

KK

( 6 )

[ ** ]

TERMINAL CONNECTIONS + [ ** ]

(according to the positioning scheme on p. 3/1.50.04):

= no terminal connection

HH = n° 1 rapid clamp kit with flanges (IN / OUT)

JJ = n° 1 rapid clamp kit with wall fixing screws + flanges (IN / OUT)

KK = n° 1 rapid clamp kit with wall fixing brackets + flanges (IN / OUT)

WALL CONNECTION:

REGULATOR and FILTER-REGULATOR

S = Bracket (only with clamps mod. X o HH)

Codes examples: MX3-1-R..XV..-S; MX3-1-R..XV..-HSH

-

LH

( 7 )

FLOW DIRECTION:

= from left to right (standard)

LH = from right to left

( 4 ) + ( 5 ) + [ * ]

REPEATABLE COMBINATION for a “n” number of times

CONFIGURATOR OF ASSEMBLED GROUPS SERIES MX

MX 2 -

3/8 -

V01 X F00 -

KK -

LH