115

a i r p i l o t v a l v e s

3

Dimensions in millimeters (mm)

Mod.

VSO 425-M5

VSO 425-M5

Mod.

VSO 426-04

Quick exhaust valves are commonly used to increase the speed of

cylinders or for rapid depressurisation of tanks containing compressed

air. The models

VSO 425-M5

and

VSO 426-04

are specially

designed for mounting on solenoid valves and valves incorporating a

5/32” O.D. port. We recommend that a silencer be mounted on the

outlet (2931-M5).

Materials used:

- OT58 (brass) body, Nickel Plated

- Buna-N seals

Nominal flowrate

from P → A Qn* 50 NL/min. (1.76 SCFM)

from A → R Qn* 100 NL/min. (3.53 SCFM)

Qn* = determinated with 6 bar (87 psi) and DP = 1 bar (14.5 psi)

Minimum operating pressure = 1 bar (14.5 psi)

Cv Rating

from P → A: Cv = 0.05

from A → R: Cv = 0.1

DIMENSIONS (in inches)

Flow (Qn)

Inlet P

A Exhausting A

R

Mod.

B

NPTF

D

E

L1 L2 SW SCFM Cv

SCFM

Cv

VSC 588-02

1/8” 1.102 0.689 1.437 .984 .551 22.9 0.68 35.3

1.05

VSC 544-04

1/4” 1.299 0.807 1.653 1.122 .669 38.8 1.16 67.1

2.00

VSC 538-06

3/8” 1.692 1.063 2.263 1.555 .944 158.9 4.73 222.5 6.62

VSC 522-08

1/2” 1.692 1.063 2.302 1.555 .944 158.9 4.73 222.5 6.62

Quick exhaust valves Series VSC

Quick exhaust valves are commonly used to increase the

speed of cylinders or for rapid depressurisation of tanks

containing compressed air. We recommend that a silencer

be mounted on the outlet.

Materials used:

- OT58 (brass) body, Nickel Plated

- Desmopan seal (polyurethane)

VSC 588-02

Qn = P → A 650 NL/min

Qn = A → R 1000 NL/min

Minimum operating pressure = 0,5 bar

VSC 544-04

Qn = P → A 1100 NL/min

Qn = A → R 1900 NL/min

Minimum operating pressure = 0,3 bar

VSC 538-06

Qn = P → A 4500 NL/min

Qn = A → R 6300 NL/min

Minimum operating pressure = 0,2 bar

VSC 522-08

Qn = P → A 4500 NL/min

Qn = A → R 6300 NL/min

Minimum operating pressure = 0,2 bar

* Qn = determinated with 6 bar and Dp = 1 bar

Quick exhaust valves Series VSO (connections are all 5/32” OD)

VSO 426-04

Cv = .05 - 4.73