Products designed for industrial applications.

General terms and conditions for sale are available on

www.camozzi.com.

Series AP proportional valves

CATALOGUE

2

/15.01.01

2

>

Release 8.8

CONTROL >

CONTROL

Series AP

directly operated proportional valves

2/2-way proportional valves, NC

Sizes: 16 - 22 mm

Series AP directly operated 2/2-way

proportional solenoid valves, NC, with

nominal diameters range from 0.8 to

2.4 mm, can be used where an open

loop flow control is required, with gas

mixtures, to control free flows or blows,

or emptying chambers using vacuum.

Series AP proportional valves have

been manufactured to optimize and

reduce friction and stick-slip effects. The

output flow is proportional to the control

signal. As they can work also in vacuum,

a minimum working pressure is not

required.

»

»

PWM or current operation

»

»

Open loop flow control

»

»

Also suitable for

use with vacuum

Several versions available:

»

»

with body in PVDF

(size 16mm only),

»

»

with rear flanged bodies

»

»

with lower flanged bodies,

»

»

suitable for use with oxygen

»

»

Seals in FKM and NBR

GENERAL DATA

Function

Operation

Ports

2/2 NC

proportional directly operated

M5 - G1/8 - with rear flanges - with lower flanges

Hysteresis

Repeatibility

Size 16mm: 12% FS - Size 22mm: 10% FS

Size 16mm: 7% FS - Size 22mm: 7% FS

Operating temperature 0 ÷ 60°C

Medium

filtered compressed air, unlubricated, according to ISO 8573-1 class 3.4.3, inert gas.

All the valves are suitable for use with oxygen.

Installation

any position

Materials

body = brass / PVDF (for size 16mm only)

seals = NBR and FKM

Nominal resistance

Rated current

GP7 GPH U711 U712

193 ohm 48 ohm 85 ohm 22 ohm

125 mA 250 mA 271 mA 542 mA

NOTE: Having a counterpressure on the outlet connection of at least 25% of the inlet pressure ensures the good functioning of the valve and improves its

performance. Example: with inlet Pressure = 1 bar on the outlet connection, a min. counterpressure of 250 mbar is recommended.