Background Image
Table of Contents Table of Contents
Previous Page  843 / 1278 Next Page
Information
Show Menu
Previous Page 843 / 1278 Next Page
Page Background

Products designed for industrial applications.

General terms and conditions for sale are available on

www.camozzi.com.

2

Series AP proportional valves

CONTROL >

CATALOGUE

>

Release 8.8

/15.01.06

2

CONTROL

Maximum flow according to the inlet

pressure

DIAGRAM LEGEND:

Q = flow (Nl/min)

I = current (A)

RESPONSE TIMES calculated according to the maximum flow at each operating pressure. [ Electromechanical response time: 10 ms ]

ø

Pin [bar]

Load response time [ms]

Exhaust response time [ ms ]

0% - 10% 0% - 90% 10% - 90%

100% - 90% 100% - 10% 90% - 10%

0.8 mm

10

12 43 31

11 39 28

1 mm

8

12 42 30

11 38 27

1.2 mm

6

10 41 31

11 41 30

1.6 mm

4

10 40 30

11 40 29

MAXIMUM FLOW AND RESPONSE TIMES - size 16mm

Maximum flow according to the inlet

pressure

DIAGRAM LEGEND:

Q = flow (Nl/min)

I = current (A)

RESPONSE TIMES calculated according to the maximum flow at each operating pressure. [ Electromechanical response time: 10 ms ]

ø

Pin [bar]

Load response time [ms]

Exhaust response time [ ms ]

0% - 10% 0% - 90% 10% - 90%

100% - 90% 100% - 10% 90% - 10%

1 mm

10

10 36 26

10 36 26

1.2 mm

8

10 45 35

12 38 26

1.6 mm

6

12 45 33

12 40 28

2 mm

5

12 42 30

11 34 26

2.4 mm

4

11 45 34

12 44 32