Background Image
Table of Contents Table of Contents
Previous Page  866 / 1278 Next Page
Information
Show Menu
Previous Page 866 / 1278 Next Page
Page Background

Products designed for industrial applications.

General terms and conditions for sale are available on

www.camozzi.com.

Series K8P electronic proportional micro regulator

CATALOGUE

2

/15.37.01

2

>

Release 8.8

CONTROL >

CONTROL

Series K8P

electronic proportional micro regulator

Proportional regulator for the pressure control

Series K8P electronic proportional micro regulators have evolved from our Series K8

mini-solenoid valves. Series K8P regulators guarantee excellent pressure regulation, fast

response times, self-regulation and low energy consumption.

Series K8P is a high performance proportional pressure regulator which is suitable for

use in all applications where high precision, quick response times and low consumption

are required.

The K8P regulator adjusts the outlet

pressure through the operation of two K8

monostable valves according to the inlet

signal and to the retroactivity of the internal

pressure sensor. A self-adjusting function

has been integrated into the regulator

control algorithm to guarantee the highest

levels of performance apart from the volume

connected.

»

»

High precision

»

»

Reduced response times

»

»

Minimum consumption

»

»

Self-regulation function

»

»

Flexibility of use

»

»

Compact design

GENERAL DATA

Fluids

filtered compressed air, unlubricated, according to ISO 8573-1 class 3.4.3, inert gas

Range of regulated pressure

0.5 ÷ 10 bar

0.15 ÷ 3 bar

Max inlet pressure

11 bar (0.5 ÷ 10 bar)

4 bar (0.15 ÷ 3 bar)

Operating pressure

0 ÷ +50°C

Analogical input

0-10 V DC 4-20 mA Ripple ≤ 0,2%

Analogical output

0.5 - 9.5 V [ Feedback ]

Analog input impedance

20.000 Ω for versions 0-10 V

250 Ω for versions 4-20 mA

Maximum flow

Inlet P 10 bar - regulated P 6 bar 12 l/min

Inlet P 4 bar - regulated P 3 bar 6 l/min

Supply / Use

24 V - ~1 W

Function

3/2 NC

Linearity

≤ ± 1% FS

Hysteresis

±0,5% FS

Repeatability

±0.5% FS

Minimal set point change

50 mV => 50 mB ( 10 bar ) - 100mV => 30 mB ( 3 bar )

Electrical connection

M8 4 Pin ( Male )

In compliance with the European Directive 2004/108/EC