Background Image
Table of Contents Table of Contents
Previous Page  881 / 1278 Next Page
Information
Show Menu
Previous Page 881 / 1278 Next Page
Page Background

Products designed for industrial applications.

General terms and conditions for sale are available on

www.camozzi.com.

2

Series ER100 digital electro-pneumatic regulators

CONTROL >

CATALOGUE

>

Release 8.8

/15.50.02

2

CONTROL

Model

ER104-5 0/1/2 X

Analog type

ER104-5 P X

Parallel type

Fluid

filtered compressed air, unlubricated,

according to ISO 8573-1 class 3.4.3, inert gas

filtered compressed air, unlubricated,

according to ISO 8573-1 class 3.4.3, inert gas

Max. working pressure

7 bar

7 bar

Min. working pressure

Control pressure +

max. control pressure x 0,2

Control pressure +

max. control pressure x 0,2

Pressure control range

0,3 ÷ 5 bar

0,3 ÷ 5 bar

Class protection

IP40

IP40

Power supply voltage

24 V DC +/- 10%

(stabilized power supply

with a ripple rate of 1% or less)

24 V DC +/- 10%

(stabilized power supply

with a ripple rate of 1% or less)

Consumption current

0.15 A

(or less rush current 0.6 A

or less when power is turned on)

0.15 A

(or less rush current 0.6 A

or less when power is turned on)

Input signal

(Input impendance)

0 ÷ 10 V DC (6,7 kΩ)

0 ÷ 5 V DC (10 kΩ)

4 ÷ 20 mA DC ( 250 Ω)

10 bit

Preset input

8 points

N/A

Output signal

Note 1

Analog output 1-5 VDC

(load to be connected impedance 500 kW or more)

Switch output NPN or PNP, open collector output,

30 V or less, 50 mA or less, voltage drop 2.4 or less,

compatible for use with PLC or Relay

Analog output 1-5 VDC

(load to be connected impedance 500 kW or more)

Switch output NPN or PNP, open collector output,

30 V or less, 50 mA or less, voltage drop 2.4 or less,

compatible for use for PLC or Relay

Error Output signal

NPN or PNP

open collector output, 30 V or less, 50 mA or less,

voltage drop 2,4 V or less,

compatible for use with PLC or Relay

NPN or PNP

open collector output, 30 V or less, 50 mA or less,

voltage drop 2,4 V or less,

compatible for use with PLC or Relay

Direct memory setting

0,05 ÷ 5 bar

minimum input width 0,01 bar

0,05 ÷ 5 bar

minimum input width 0,01 bar

Hysteresis

Note 2

0.5% F.S. or less

0.5% F.S. or less

Linearity

Note 2

±0.3% F.S. or less

±0.3% F.S. or less

Resolution

Note 2

0.2% F.S. or less

0.2% F.S. or less

Repeatability

Note 2

0.3% F.S. or less

0.3% F.S. or less

Temperature characteristics:

Zero point fluctation

0.15% F.S./°C or less

0.15% F.S./°C or less

Temperature characteristics:

Span point fluctation

0.07% F.S./°C or less

0.07% F.S./°C or less

Max. flow rate (ANR )

Note 3

400 l/min (see diagram)

400 l/min (see diagram)

Step response time

No load

Note 4

0.2 sec. or less

0.2 sec. or less

Step response time

1000 cm³ load

Note 4

0.8 sec. or less

0.8 sec. or less

Mechanical vibration proof

98 m/s² or less

98 m/s² or less

Ambient temperature

5°C ÷ 50 °C

5°C ÷ 50 °C

Fluid temperature

5°C ÷ 50 °C

5°C ÷ 50 °C

Connection port size

G1/4

G1/4

Mounting direction

Free

Free

Weight

250g

250g

Note 1:

Select either analog or switch output.

Note 2:

This characteristic is guaranteed within a regulation range between 10 and 90% of the full

scale, with a power voltage of 24V±10%, a supply pressure of 1 bar higher compared with

the set pressure (ex. regulation of 3 bar, supply pressure of 3+1 = 4 bar) and a volume

connected to the outlet without any loss. In applications with great air consumption, such

as the blowing, the indicated tolerance may change.

Note 3:

The above apply when working pressure

and control pressure are maximum

Note 4:

The above apply when working pressure is maximum

and the step is as follows:

50% F.S. -> 100%F.S.

50% F.S. -> 60% F.S.

50% F.S. -> 40% F.S.

GENERAL DATA ER104-5xxx