134
2
SHORT FORM CATALOGUE
>
Release 8.8
2
CONTROL
Products designed for industrial applications.
General terms and conditions for sale are available on
www.camozzi.com.CONTROL >
Series K8P
Series K8P electronic proportional micro regulator
Proportional regulator for the pressure control
Standard Sub-base
Note: the use of a silencer
on the exhaust is recommended *
* = Mod. 2939 4
Mod. K8P-AS
Light Sub-base
Note: the use of a silencer on the
exhaust is recommended *
* = Mod. 2931 M5
2938 M5
2901 M5
Mod. K8P-AL
Light Sub-base for the pressure remote reading
Note: the use of a silencer on the
exhaust is recommended *
* = Mod. 2931 M5
2938 M5
2901 M5
In the version Light sub-base for the pressure
remote reading it is also possible to use the
fixing bracket B2-E531
Mod. K8P-AT
Accessories
Mounting brackets for DIN rail
DIN EN 50022 (7,5 mm x 35 mm - width 1)
Supplied with:
1x plates
1x screws M4x6 UNI 5931
Note: this accessory cannot be used with
the Light sub-base version.
Mod. PCF-K8P
Bracket for horizontal mounting,
for standard sub-base
Supplied with:
1x mounting bracket
2x screws M3x8 UNI 5931
Mod. K8P-B1
Circular M8 4-pole connectors, Female
With PU sheathing, non shielded cable
Protection class: IP65
Mod. CS-DF04EG-E200 (cable 2 m)
CS-DF04EG-E500 (cable 5 m)
CS-DR04EG-E200 (cable 2 m)
CS-DR04EG-E500 (cable 5 m)
Mod. K8P-0-D5*2-0
K8P-0-E5*2-0
K8P-L-E5*2-0
K8P-L-D5*2-0
K8P-S-D5*2-0
K8P-S-E5*2-0
K8P-T-D5*2-0
K8P-T-E5*2-0
* = according to the desired command, put: 2 (0-10 V DC) or 3 (4-20 mA)
CODING EXAMPLE
K8P
SERIES
0
BODY DESIGN:
0 = Stand alone - S = Standard Sub-base - L = Light Sub-base - T = Light Sub-base for the pressure remote reading
D
WORKING PRESSURE:
D = 0 -10 bar - E = 0 - 3 bar
5
VALVE FUNCTIONS:
5 = 2-way NC
2
COMMAND:
2 = 0-10 V DC - 3 = 4-20 mA
2
OUTPUT SIGNAL:
2 = 0-10 V
0
CABLE LENGTH:
0 = without cable - 2F = straight cable, 2 m - 2R = right angle cable (90 degrees), 2 m - 5F = straight cable, 5 m - 5R = right angle cable (90 degrees), 5 m
APPLICATIONS
The K8P proportional regulator can be used as a pilot valve to control the opening of high flow valves or to check the high flow pressure regulators proportionally
(version with sub-base for the pressure remote reading). It enables proportional control of power in lifting systems and can be used with inert gas to maintain a constant pressure
in pneumatic cylinders or expansion valve chambers. It has also been designed to maintain a constant pressure during the pulling power applied to the wires in winding machines,
to modulate pressure during the smoothing process in woodworking machines or to adjust the opening of diaphragm valves.
K8P -
0
-
D 5
2
2
-
0