Background Image
Table of Contents Table of Contents
Previous Page  143 / 210 Next Page
Information
Show Menu
Previous Page 143 / 210 Next Page
Page Background

134

2

SHORT FORM CATALOGUE

>

Release 8.8

2

CONTROL

Products designed for industrial applications.

General terms and conditions for sale are available on

www.camozzi.com.

CONTROL >

Series K8P

Series K8P electronic proportional micro regulator

Proportional regulator for the pressure control

Standard Sub-base

Note: the use of a silencer

on the exhaust is recommended *

* = Mod. 2939 4

Mod. K8P-AS

Light Sub-base

Note: the use of a silencer on the

exhaust is recommended *

* = Mod. 2931 M5

2938 M5

2901 M5

Mod. K8P-AL

Light Sub-base for the pressure remote reading

Note: the use of a silencer on the

exhaust is recommended *

* = Mod. 2931 M5

2938 M5

2901 M5

In the version Light sub-base for the pressure

remote reading it is also possible to use the

fixing bracket B2-E531

Mod. K8P-AT

Accessories

Mounting brackets for DIN rail

DIN EN 50022 (7,5 mm x 35 mm - width 1)

Supplied with:

1x plates

1x screws M4x6 UNI 5931

Note: this accessory cannot be used with

the Light sub-base version.

Mod. PCF-K8P

Bracket for horizontal mounting,

for standard sub-base

Supplied with:

1x mounting bracket

2x screws M3x8 UNI 5931

Mod. K8P-B1

Circular M8 4-pole connectors, Female

With PU sheathing, non shielded cable

Protection class: IP65

Mod. CS-DF04EG-E200 (cable 2 m)

CS-DF04EG-E500 (cable 5 m)

CS-DR04EG-E200 (cable 2 m)

CS-DR04EG-E500 (cable 5 m)

Mod. K8P-0-D5*2-0

K8P-0-E5*2-0

K8P-L-E5*2-0

K8P-L-D5*2-0

K8P-S-D5*2-0

K8P-S-E5*2-0

K8P-T-D5*2-0

K8P-T-E5*2-0

* = according to the desired command, put: 2 (0-10 V DC) or 3 (4-20 mA)

CODING EXAMPLE

K8P

SERIES

0

BODY DESIGN:

0 = Stand alone - S = Standard Sub-base - L = Light Sub-base - T = Light Sub-base for the pressure remote reading

D

WORKING PRESSURE:

D = 0 -10 bar - E = 0 - 3 bar

5

VALVE FUNCTIONS:

5 = 2-way NC

2

COMMAND:

2 = 0-10 V DC - 3 = 4-20 mA

2

OUTPUT SIGNAL:

2 = 0-10 V

0

CABLE LENGTH:

0 = without cable - 2F = straight cable, 2 m - 2R = right angle cable (90 degrees), 2 m - 5F = straight cable, 5 m - 5R = right angle cable (90 degrees), 5 m

APPLICATIONS

The K8P proportional regulator can be used as a pilot valve to control the opening of high flow valves or to check the high flow pressure regulators proportionally

(version with sub-base for the pressure remote reading). It enables proportional control of power in lifting systems and can be used with inert gas to maintain a constant pressure

in pneumatic cylinders or expansion valve chambers. It has also been designed to maintain a constant pressure during the pulling power applied to the wires in winding machines,

to modulate pressure during the smoothing process in woodworking machines or to adjust the opening of diaphragm valves.

K8P -

0

-

D 5

2

2

-

0