138

3

SHORT FORM CATALOGUE

>

Release 8.8

3

TREATMENT

Products designed for industrial applications.

General terms and conditions for sale are available on

www.camozzi.com.

TREATMENT >

Series MD

Series MD activated carbon filters

Ports with interchangeable cartridges: threaded (1/8, 1/4, 3/8) or integrated with super-rapid fitting for tube

with ø 6, 8 and 10 mm. Modular assembly

Bowl with technopolymer cover and bayonet-type mounting

CODING EXAMPLE

MD 1 - FCA 0 - 1/8

FC02 =

activated carbon filter with

visual blockage indicator

FC01 =

activated

carbon filter

MD

SERIES

1

DIMENSION:

1 = 42 mm

FCA

ACTIVATED CARBON FILTER

0

VISUAL BLOCKAGE INDICATOR:

0 = not present

1 = present

1/8

PORTS (IN - OUT)*:

= without cartridges

1/8 = G1/8

1/4 = G1/4

3/8 = G3/8

6 = tube ø 6

8 = tube ø 8

10 = tube ø 10

* NOTE: if the inlet (IN) cartridge is different from the outlet (OUT) cartridge,

both dimensions shall be indicated.

Example: MD1-FCA1-1/4-10

Series MD pressure regulators

Ports with interchangeable cartridges: threaded (1/8, 1/4, 3/8) or integrated with super-rapid fitting for tube

with ø 6, 8 and 10 mm

Versions: single, combined with other functions, Manifold

CODING EXAMPLE

MD 1 - R T 0 0 - 1/4 - ■ - ●

MD

SERIES

1

DIMENSION:

1 = 42 mm

R

TYPER OF REGULATOR:

R = pressure regulator - M = Manifold pressure regulator

T

OPERATING PRESSURE (1 bar = 14,5 psi):

0 = 0.5 ÷ 10 bar

2 = 0 ÷ 2 bar

4 = 0 ÷ 4 bar

7 = 0.5 ÷ 7 bar

T = calibrated **

B = locked **

0

DESIGN TYPE:

0 = with relieving - 1 = without relieving

2 = with relieving and by-pass valve - 3 = without relieving, with by-pass valve

0

PRESSURE GAUGE:

0 = without pressure gauge (with 1/8 port)

1/4

PORTS (IN - OUT)*:

= without cartridges

1/8 = G1/8

1/4 = G1/4

3/8 = G3/8

6 = tube ø 6

8 = tube ø 8

10 = tube ø 10

* NOTE: if the inlet (IN) cartridge is different from the outlet (OUT) cartridge,

both dimensions shall be indicated.

Example: MD1-R020-1/4-10

PR01 =

regulator

without relieving

PR02 =

regulator

with relieving

PR03 =

regulator

with relieving

and by-pass valve

PR04 =

regulator

without relieving,

with by-pass valve

RM01 =

manifold regulator

with relieving

RM02 =

manifold regulator

without relieving

RM03 =

manifold regulator

with relieving

and by-pass valve

RM04 =

manifold regulator

without relieving,

with by-pass valve

** NOTE: IF THE REGULATOR IS CALIBRATED OR LOCKED, AFTER THE PORTS

ADD THE INLET PRESSURE “■” AND THE OUTLET PRESSURE “●”

INLET PRESSURE: ■ = enter the SUPPLY pressure value

OUTLET PRESSURE: ● = enter the OUTLET pressure value for the LOCKED regulator

or the maximum value of the ADJUSTABLE pressure for the CALIBRATED regulator.

Example of a calibrated regulator with Inlet Pressure = 6.3 bar and Outlet Pressure = 4.5 bar.

Complete part number: MD1-RT00-1/4-6.3-4.5

New