Products designed for industrial applications.
General terms and conditions for sale are available on
www.camozzi.com.TREATMENT >
Series MD
Series MD lockable isolation 3/2-way valves
Ports with interchangeable cartridges: threaded (1/8, 1/4, 3/8) or integrated with super-rapid fitting
for tube with ø 6, 8 and 10 mm. Modular. Manual, electro-pneumatic, servo-pilot and pneumatic control
Series MD soft start valves
Ports with interchangeable cartridges: threaded (1/8, 1/4, 3/8) or integrated with super-rapid fitting
for tube with Ø 6, 8 and 10 mm. Modular assembly
Series MD take-off blocks
Module with interchangeable cartridges: threaded (1/8, 1/4, 3/8) or integrated with super-rapid fitting
for tube with Ø 6, 8 and 10 mm (5-way version). Intermediate joining cartridge (3-way version)
CODING EXAMPLE
MD 1 -
B 00 - 1/8
CODING EXAMPLE
MD 1 -
V 01 - 1/8
MD
SERIES
1
DIMENSION:
1 = 42 mm
V
3/2-WAY VALVE
01
DESIGN TYPE:
01 = lockable manual control
16 = electro-pneumatic control, Push & Turn manual override
16IL = electro-pneumatic control, bistable manual override, lever type
16IM = electro-pneumatic control, monostable manual override
16IT = electro-pneumatic control without manual override
36 = pneumatic control
1/8
PORTS (IN - OUT) *:
= without cartridges
1/8 = G1/8 - 1/4 = G1/4 - 3/8 = G3/8
6 = tube ø 6 - 8 = tube ø 8 - 10 = tube ø 10
* NOTE: if the inlet (IN) cartridge is different from the outlet (OUT) cartridge,
both dimensions shall be indicated. Example: MD1-V01-1/4-1/8
CODING EXAMPLE
MD 1 -
AV -
1/8
MD
SERIES
1
DIMENSION:
1 = 42 mm
AV
SOFT START VALVE
1/8
PORTS (IN - OUT) *:
= without cartridges - 1/8 = G1/8 - 1/4 = G1/4 - 3/8 = G3/8
6 = tube ø 6 - 8 = tube ø 8 - 10 = tube ø 10
* NOTE: if the inlet (IN) cartridge is different from the outlet (OUT) cartridge,
both dimensions shall be indicated. Example: MD1-AV-1/4-1/8
AVP1 =
soft start valve
MD
SERIES
1
DIMENSION:
1 = 42 mm
B
TAKE-OFF BLOCK
00
DESIGN TYPE:
00 = standard derivation
1/8
PORTS (IN - OUT) *:
= without cartridges - 1/8 = G1/8 - 1/4 = G1/4 - 3/8 = G3/8
6 = tube ø 6 - 8 = tube ø 8 - 10 = tube ø 10
* NOTE: if the inlet (IN) cartridge is different from the outlet (OUT) cartridge,
both dimensions shall be indicated. Example: MD1-B00-3/8-10
BL01 =
take-off block
New
New
New
EV10 =
valve with electro-pneumatic
control, bistable manual override,
lever type
EV54 =
valve with electro-pneumatic
control, monostable manual override
EV55 =
valve with electro-pneumatic
control without manual override
YES1 =
valve with pneumatic
control
VN27 =
valve with lockable
manual control