Background Image
Table of Contents Table of Contents
Previous Page  9 / 20 Next Page
Information
Show Menu
Previous Page 9 / 20 Next Page
Page Background

09

CPU Module

This serial module can interface with several protocols such

as Ethernet IP, EtherCat, ProfiNet, Powerlink, Profibus,

CanOpen, Devicenet, Modbus and Sercos.

It can be connected to various modules: digital inputs

with modularity at 8 and 4, digital outputs with 10-W

power each, input modules and analog outputs with 10-bit

resolution, direct interface modules for valve islands F, H

and 3, so as to provide a solution in a single block.

With the initial module of the subnet it’s also possible

to create extensions in a system or on a machine to control

more valve islands. In this way the CPU potentialities can

be fully exploited and the slave modules can be connected

on it in the SPI-Ethernet subnet. The CPU module has a

Bus IN connection and the Bus OUT of the main network,

which can handle a maximum of 1024 inputs and 1024

outputs, indicates its operating status via LEDs.

Bridge Module

This is an expansion module of the SPI-Ethernet subnet.

Like the CPU, it can be connected to the same modules,

like digital input and output modules, analog input and

output modules, direct interface modules for Series F,

H, 3 valve islands, as well as the initial module of the

subnet to further branch out or create new branches.

It has a Bus IN connection and the Bus OUT of the

SPI-Ethernet subnet indicates its operating status via

LEDs. In a SPI-Ethernet subnet it is possible to connect

as many Bridge modules as you like, up to a maximum

length of 100 meters of the entire branch.

Sub-D Adaptor Module 25 and 37 pin

This is an expansion module of the SPI-Ethernet subnet.

It can be used with all valve islands having a 25-pin

Sub-D connection (Series F, 3 and H) and with the

Series H module with 37-pin Sub-D 37 connection.

It has a Bus IN connection and the Bus OUT of the

SPI-Ethernet subnet indicates its operating status via

LEDs. The 25-pin Adaptor Module manages a fixed

number of 24 digital outs, whilst the 37-pin Adaptor

Module manages a fixed number of 32 digital outs.

Each out of both modules can deliver a maximum

of 3 W at 24 V DC. For PWM outputs it is possible

to set the value of the working frequency.

In a SPI-Ethernet subnet it is possible to connect as

many Adaptor modules as you like, up to a maximum

length of 100 meters of the entire branch.

NEWS 2015

|

CONTROL >

SERIES CX3

65

65

46.8

55

55

35.5

43.7

43.7

25.5

32.2

32.2

12

6.5

6.5

4.5

122

40.5

40.5

48.6

40.45

36.5

12.5

25 25 26 26 26 22.7

46.5

100

24

46.8

35.5

25.5

12

4.9

40.5

48.9

40

36.5

12.5

25

68

25 26 26 26 22.7

22.7

122

IN

OUT