Products designed for industrial applications.
General terms and conditions for sale are available on
www.camozzi.com.Series 3 Fieldbus valve islands
CATALOGUE
2
/3.07.01
2
>
Release 8.7
CONTROL >
CONTROL
Series 3 Fieldbus
Valve Islands
Fieldbus system combined with Series 3 solenoid valves, G1/8 ports.
Interface with: Profibus-DP, CANopen, DeviceNet. Valve functions:
2x3/2, 5/2 and 5/3-way CO CC CP
This Fieldbus system, realized with Series 3 solenoid valves (G1/8 ports) and delivered
completely assembled and tested, can accomodate up to 9 valve positions. Moreover, it
offers the possibility to manage up to 64 I/O.
It is possible to combine the pneumatic
electric modules by simply attaching them
to each other up to a maximum of 9 valve
positions. The pneumatic modularity of
2 and 3 positions offers the possibility to
create manifolds with different pressure/
exhaust supplies.
To check the suitable connectors see the
section 2/3.25.
»
»
Flexible assembly
»
»
Easy installation
»
»
Conform with standards
EN-61326-1 and EN-61010-1
GENERAL DATA AND ELECTRIC CHARACTERISTICS
Valve construction
spool type
Valve functions
5/2 - 5/3 CC CO CP - 2x3/2 NO - 2x3/2 NC - 1 3/2 NO+1 3/2 NC
Materials
AL body, stainless steel spool, NBR seals, technopolymer
Ports
Mounting
Installation
valve = G1/8 - manifold = G3/8
through holes in the valve body
in any position
Operating temperature
0-50 °C
Nominal flow rate
Qn 700 Nl/min
Nominal diameter
7 mm
Fluid
Filtered air, without lubrication. If lubricated air is used, it is recommended to use ISO VG32 oil and to never interrupt
the lubrication.
FieldBus protocol
3F8: Profibus-DP - 3R8: DeviceNet - 3G8: CANopen
Fieldbus signalling Led
3F8: 1 led green RUN, 1 led red DIA, 1 led red BF
3R8: 1 led green IO, 1 led red NS, 1 led red MS
3G8: 1 led green RUN, 1 led red DIA, 1 led red BF
Valve signalling Led
yellow led
Logical supply voltage
24VDC (-15% / + 20%)
Power supply voltage
24VDC (for the tolerance, consider the total loads of the connected inputs)
Duty cycle
ED 100%
Maximum number of nodes
3F8: 32/127 - 3R8: 64 - 3G8: 127
Maximum Baud rate
3F8: 12 Mbit/sec - 3R8: 500 Kbit/sec - 3G8: 1 Mbit/sec
Solenoid power consumption
3W
Electric power supply connector
M12
Number of digital input / output
64 / 64
Maximum input / output absorption 1,5 A / 3 A (the total absorption must never exceed 3,5 A)
Protections
against overload and reverse polarity
Protection class
IP65
* The voltage range can change according to the range required by the connected external elements.