2
CONTROL
Valve Island - characteristics
Bus-In Bus-Out system for connection to the Fieldbus network. Double electrical supplies (1 for control and 1 for power). Addressing
of every node via rotary switches. Leds indicating the working state. Handling of a max n° of 64 inputs and 64 outputs (I/O). Electric
outputs mod. on the right side of the node are available with connection M12 duo and/or Sub-D a 37 poles and connected to pneumatic
sub-bases (max 9 pos. mono/bistable valves). It’s possible to pilot other multipole island valves and/or systems, managed through digi-
tal signals, using connection cables 37/25 pin. Similarly, on the left side of the node it’s possible to connect Input Mod. 8 (8 connections
M8 every Mod.). All Mod. I/O can be easily inserted thanks to their direct connection to the plate. Manuals and configuration files are
available on our website:
http://catalogue.camozzi.com/Downloads.DRAWING LEGEND: 1 = digital inputs module 4 = digital outputs module connector 37 poles
2 = Fieldbus module 5 = penumatic/electric interface module + foot
3 = digital outputs module M12 connector