Products designed for industrial applications.

General terms and conditions for sale are available on

www.camozzi.com.

2

Series H valve islands

CONTROL >

CATALOGUE

>

Release 8.7

/3.15.25

2

CONTROL

H

SERIES

P

TYPE:

P = Pneumatic

A = Accessories

5

SIZE:

1 = 10.5

2 = 21

5 = Mixed

F

ELECTRICAL CONNECTION:

F = Profibus-DP

G = CANopen

R = DeviceNet

3A

INPUT MODULES:

0 = no module

A = 8 Input M8

C

OUTPUT MODULES:

0 = no module

B = 4 Output M12 DUO

C = 8 Output Sub-D 37 pin

D = 16 Output Sub-D 37 pin

E = 24 Output Sub-D 37 pin

F = 32 Output Sub-D 37 pin

ABCS

SUB-BASES FOR SOLENOID VALVES

Sub-bases for 2 solenoid valves size 1 (*):

A (AZ) = M7 threads

B (BZ) = 4 fittings for tube Ø4

C (CZ) = 4 fittings for tube Ø6

D (DZ) = channel 1, 3, 5 closed - M7 threads

E (EZ) = channel 1, 3, 5 closed - cartridges tube Ø4

F (FZ) = channel 1, 3, 5 closed - cartridges tube Ø6

G (GZ) = channel 3, 5 closed - M7 threads

H (HZ) = channel 3, 5 closed - cartridges tube Ø4

I (IZ) = channel 3, 5 closed - cartridges tube Ø6

L (LZ) = channel 1 closed - M7 threads

M (MZ) = channel 1 closed - cartridges tube Ø4

N (NZ) = channel 1 closed - cartridges tube Ø6

(*) Sub-bases with “Z” at the end of their code

are used with monostable solenoid valves

Sub-bases for solenoid valves size 2:

Q = G 1/8 threads

R = cartdriges tube Ø6

S = cartdriges tube Ø8

SUB-BASES FOR SUPPLY

Sub-bases for pneumatic supply:

X = supplementary supply and exhaust

Y = supplementary supply and exhaust

with integrated silencer

W = supply from the exhausts

Sub-bases for electrical supply:

K = separation of electrical supply

and supplementary pneumatic supply

SEALS

T = diaphragm seal - channel 1;3;5

U = diaphragm seal - channel 1

V = diaphragm seal - channel 3; 5

MMCCBBB

SOLENOID VALVES

Size 1 and Size 2:

M = 5/2 Monostable

B = 5/2 Bistable

V = 5/3 Centres Closed C = 2 x 3/2 NC

A = 2 x 3/2 NO

G = 1 x 3/2 NC + 1 x 3/2 NO

E = 2 x 2/2 NC

F = 2 x 2/2 NO

I = 1 x 2/2 NC + 1 x 2/2 NO

L = free position

Solenoid valve + Pressure regulator

on channel 1 - Size 2 ONLY:

N = 5/2 Monostable

P = 5/2 Bistable

Q = 5/3 CC

R = 2 x 3/2 NC

S = 2 x 3/2 NO

T = 1 x 3/2 NC + 1 x 3/2 NO

U = 2 x 2/2 NC

X = 2 x 2/2 NO

Y = 1 x 2/2 NC + 1 x 2/2 NO

A

TERMINAL PLATES

Threaded:

A = 1; 12/14 in common

3/5; 82/84 threaded ports

B = 1; 12/14 separated

3/5; 82/84 threaded ports

C = 1; 12/14 in common

3/5; 82/84 with integrated silencer

D = 1; 12/14 separated

3/5; 82/84 with integrated silencer

TERMINAL PLATES

With cartridges Ø 8 :

E = 1; 12/14 in common

3/5; 82/84 conveyable

F = 1; 12/14 separated

3/5; 82/84 conveyable

G = 1; 12/14 in common

3/5; 82/84 with integrated silencer

H = 1; 12/14 separated

3/5; 82/84 with integrated silencer

TERMINAL PLATES

With cartridges Ø 10 :

I = 1; 12/14 in common

3/5; 82/84 conveyable

L = 1; 12/14 separated

3/5; 82/84 conveyable

M = 1; 12/14 in common

3/5; 82/84 with integrated silencer

N = 1; 12/14 separated

3/5; 82/84 with integrated silencer

X, Y and K sub-bases will be equipped with threads or cartridges of the same size of port 1, see the choice “Type of terminal plates”. In presence of identical consequent codes

both for sub-bases and for valves, you need to substitute the letter with the number. Ex: HP5P-AAA-XC-ABCS-MMCCBBB-A is converted to Ex: HP5P-3A-XC-2M2C3B-A.

CODING EXAMPLE - INDIVIDUAL FIELDBUS VERSION

H P 5 F - 3A - C - ABCS - MMCCBBB - A