Products designed for industrial applications.
General terms and conditions for sale are available on
www.camozzi.com.Series HN valve islands
CATALOGUE
2
/3.40.05
2
>
Release 8.8
CONTROL >
CONTROL
HN
SERIES
5
SIZE:
1 = 10.5
2 = 21
5 = Mixed
01
PROTOCOL:
01 = PROFIBUS-DP
02 = DeviceNet
03 = CANopen
04 = EtherNet/IP
05 = EtherCAT
06 = PROFINET
99 = Expansion module
ABCD
INPUT / OUTPUT MODULES:
0 = no module
INPUT / OUTPUT MODULES:
A = 8 Digital Inputs M8
B = 4 Digital Inputs M8
C = 2 Analog Inputs 4-20mA
D = 2 Analog Inputs 0-10V
E = 1 Analog Input 4-20mA + 1 Input 0-10V
Q = 4 Digital Outputs M12 duo
R = 2 Analog Outputs 4-20mA
T = 2 Analog Outputs 0-10V
U = 1 Analog Output 4-20mA + 1 Output 0-10V
V = 1 Analog Output 4-20mA + 1 Input 0-10V
Z = 1 Analog Output 4-20mA + 1 Input 4-20mA
K = 1 Analog Output 0-10V + 1 Input 0-10V
Y = 1 Analog Output 0-10V + 1 Input 4-20mA
INPUT / OUTPUT MODULES:
S = Initial subnet module
2Q4AZ2A
SUBBASES
FOR 2 SOLENOID VALVES SIZE 1 (*):
A (AZ) = M7 threads
B (BZ) = 4 fittings for tube Ø4
C (CZ) = 4 fittings for tube Ø6
D (DZ) = channel 1, 3, 5 closed; M7 threads
E (EZ) = channel 1, 3, 5 closed; cartridges tube Ø4
F (FZ) = channel 1, 3, 5 closed; cartridges tube Ø6
G (GZ) = channel 3, 5 closed; M7 threads
H (HZ) = channel 3, 5 closed; cartridges tube Ø4
I (IZ) = channel 3, 5 closed; cartridges tube Ø6
L (LZ) = channel 1 closed; M7 threads
M (MZ) = channel 1 closed; cartridges tube Ø4
N (NZ) = channel 1 closed; cartridges tube Ø6
(*) Subbases with “Z” at the end of their code
are used with monostable solenoid valves
FOR SOLENOID VALVES SIZE 2:
Q = G 1/8 threads
R = cartridges for tube Ø6
S = cartridges for tube Ø8
SUBBASES
FOR PNEUMATIC SUPPLY:
X = supplementary supply and exhaust
Y = supplementary supply and exhaust
with integrated silencer
W = supply from the exhausts
FOR ELECTRICAL SUPPLY:
K = separation of electrical supply
SEALS:
T = diaphragm on channels 1, 3, 5
U = diaphragm seal on channel 1
V = diaphragm seal on channels 3, 5
2B8M4C
SOLENOID VALVES
Size 1 and 2:
0 = island without solenoid valves
M = 5/2 Monostable
B = 5/2 Bistable
V = 5/3 Centres Closed
C = 2 x 3/2 NC
A = 2 x 3/2 NO
G = 1 x 3/2 NC + 1 x 3/2 NO
E = 2 x 2/2 NC
F = 2 x 2/2 NO
I = 1 x 2/2 NC + 1 x 2/2 NO
L = free position
SOLENOID VALVE + PRESSURE REGULATOR
on channel 1 (size 2 only):
N = 5/2 Monostable
P = 5/2 Bistable
Q = 5/3 Centres Closed
R = 2 x 3/2 NC
S = 2 x 3/2 NO
T = 1 x 3/2 NC + 1 x 3/2 NO
U = 2 x 2/2 NC
X = 2 x 2/2 NO
Y = 1 x 2/2 NC + 1 x 2/2 NO
A
THREADED TERMINAL PLATES:
A = 1, 12/14 in common
3/5, 82/84 threaded ports
B = 1, 12/14 separated
3/5, 82/84 threaded ports
C = 1, 12/14 in common
3/5, 82/84 with integrated silencer
D = 1, 12/14 separated
3/5, 82/84 with integrated silencer
TERMINAL PLATES with
CARTRIDGES Ø 8:
E = 1, 12/14 in common
3/5, 82/84 conveyable
F = 1, 12/14 separated
3/5, 82/84 conveyable
G = 1, 12/14 in common
3/5, 82/84 with integrated silencer
H = 1, 12/14 separated
3/5, 82/84 with integrated silencer
TERMINAL PLATES with
CARTRIDGES Ø 10:
I = 1, 12/14 in common
3/5, 82/84 conveyable
L = 1, 12/14 separated
3/5, 82/84 conveyable
M = 1, 12/14 in common
3/5, 82/84 with integrated silencer
N = 1, 12/14 separated
3/5, 82/84 with integrated silencer
X, Y and K sub-bases will be equipped with threads or cartridges of the same size of port 1, see the choice “Type of terminal plates”. In presence of identical consequent codes
both for sub-bases and for valves, you need to substitute the letter with the number.
Ex: HN501-ABCD-ABCS-MMCCBBB-A is converted to HN501- ABCD-ABCS-2M2C3B-A.
CODING EXAMPLE - FIELDBUS VERSION
HN 5 01 -
ABCD -
2Q4AZ2A -
2B8M4C -
A