Background Image
Table of Contents Table of Contents
Previous Page  670 / 1278 Next Page
Information
Show Menu
Previous Page 670 / 1278 Next Page
Page Background

Products designed for industrial applications.

General terms and conditions for sale are available on

www.camozzi.com.

Series HN valve islands

CATALOGUE

2

/3.40.07

2

>

Release 8.8

CONTROL >

CONTROL

The Multipole version can be connected in a quick and secure

way thanks to the electrical connection by means of a pre-wired

cable with 25 or 37 pins with in-line or angular connection. It is

possible to create zones with differentiated power supply and

with separate pressure/exhaust. Thanks to the subbases with

monostable board, islands can be realized up to maximum of 24

coils on 20 valve positions with the 25 pin connection and 32 coils

on 28 valve positions with the 37 pin connection.

The Multipole Island of both 25 pins and 37 pins can be

connected by means of a Sub-D adaptor, also of 25 or 37 pins.

In this way a standard Multipole Island can be inserted as

expansion in the subnet of the Serial version.

MULTIPOLE VERSION and MULTIPOLE WITH SUB-D ADAPTOR VERSION

Thanks to the Series CX Multi-serial node and a special direct

interface module with the pneumatic part of the island, it is

possible to interface the Series HN with the PROFIBUS-DP,

DeviceNet, CANopen, PROFINET, EtherCAT and EtherNet/IP

serial protocols. The Fieldbus version with CPU has the same

configuration rules of a Multipole island and can be equipped

with different electric modules like digital/analog inputs/outputs of

0-10V and 4-20mA, as well as initial subnet Modules.

It is possible to insert Initial Subnet Modules in the version with

CPU module. These Modules enable to create a subnet with tree

structure or in series. On the subnet you can connect Expansion

Islands. These expansions have the same possibilities to use

the different electric modules, like digital and analog inputs and

outputs and further Initial Subnet Modules. Also with this version

the same rules as the CPU module and Multipole apply.

VERSIONS: FIELDBUS WITH CPU MODULE AND EXPANSION FIELDBUS