Background Image
Table of Contents Table of Contents
Previous Page  604 / 1278 Next Page
Information
Show Menu
Previous Page 604 / 1278 Next Page
Page Background

Products designed for industrial applications.

General terms and conditions for sale are available on

www.camozzi.com.

Solenoids

CATALOGUE

2

/2.35.05

2

>

Release 8.8

CONTROL >

CONTROL

Solenoids Mod. B8...

Mod.

Solenoid voltage

Power absorption

B8B

24 V - 50 Hz

15 VA

B8BK

24 V - 50 Hz

15 VA

B8D

110 V - 50/60 Hz

15 VA

B8DK

110 V - 50/60 Hz

15 VA

B8E

220/230 V - 50/60 Hz

15 VA

B8EK

230 V - 50/60 Hz

15 VA

B8F

220/230 V - 50/60 Hz

21 VA

B8FK

220/230 V - 50/60 Hz

21 VA

B82

12 V - DC

19 W

B82K

12 V - DC

19 W

B83

24 V - DC

19 W

B83K

24 V - DC

19 W

Electrical connection: bipolar plus earth

Norm: DIN EN 175 301-803-A

Solenoid material: PA-MXD6

The B8*K models can be used only with some

solenoid valves Series CFB

(Mod. CFB-D1..., 2/2 NO).

Further details on page 2/1.30.03.

Solenoid Mod. H8.. for potentially explosive ambients

Certification in compliance with

EN 60079-0 EN 60079-18

ATEX :

II 2G Ex mb IIC T4 Gb

II 2D Ex mb IIIC T135°C Db

I M2 Ex mb I Mb

INERIS 06ATEX0002X

IECEx :

Ex mb IIC T4 Gb

Ex mb IIIC T135°C Db

Ex mb I Mb

IECEx INE 15.0053X

Mod.

Solenoid voltage

Power absorption

H83I

24 V - DC

5.3 W

H8BI

24 V - 50/60 Hz

5.3 W

H8CI

48 V - 50/60 Hz

5.3 W

H8DI

110 V - 50/60 Hz

5.3 W

H8EI

230 V - 50/60 Hz

5.3 W

For Series NA use plate mod.

NA54-PC.

Temperature class/Max surface temperature: T4/135°C

Environment temperature: -20°C + 40°C

Connection: tripolar cable 3 m (other lenghts on request)

Incapsulating material: self-extinguishing PA.