Background Image
Table of Contents Table of Contents
Previous Page  152 / 266 Next Page
Information
Show Menu
Previous Page 152 / 266 Next Page
Page Background

135

The company reserves the right to vary models and dimensions without notice.

These products are designed for industrial applications and are not suitable for sale to the general public.

Flow Control Valves NPTF

3

NORTH AMERICAN FITTINGS & FLOW CONTROL VALVE CATALOG

>

Release 8.6

FLOW CONTROL VALVES NPTF

METER IN, METER OUT, NEEDLE ORIFICE FLOW CONTROLLERS

Flow Qn (Nl/min.) from 2 → 1 with needle OPEN: 400

Flow Qn (Nl/min.) from 2 → 1 with needle CLOSED: 280

NB: Qn is determined with a supply pressure of 6 bar and with

DP= 1 bar at the outlet

N° = of screw turns

Flow Qn (Nl/min.) from 2 → 1 with needle OPEN: 550

Flow Qn (Nl/min.) from 2 → 1 with needle CLOSED: 280

NB: Qn is determined with a supply pressure of 6 bar and with

DP= bar at the outlet

N° = of screw turns

TUBE OD 5/32”

TUBE OD 1/4”

To ensure the right choice of unidirectional flow controller, proceed as follows: calculate the quantity of air in Nl/min (see cylinder

Table); determine the stroke time of the cylinder;

refer to graph to see which controller is the right type.

In the case of bi-directional regulators, refer to the graph and check whether the flow control range is suitable for the work required.

Flow Qn (Nl/min.) from 2 ® 1 with needle OPEN: 890

Flow Qn (Nl/min.) from 2 ® 1 with needle CLOSED: 460

NB: Qn is determined with a supply pressure of 6 bar and with

DP= bar at the outlet

N° = of screw turns

TUBE OD 5/16”

TUBE OD 3/8” - 1/2”

Flow Qn (Nl/min.) from 2 ® 1 with needle OPEN: Ø 3/8”-1200/Ø1/2”-1250

Flow Qn (Nl/min.) from 2 ® 1 with needle CLOSED: Ø 3/8”-600/Ø1/2”-600

NB: Qn is determined with a supply pressure of 6 bar and with

DP= bar at the outlet

N° = of screw turns