In order to enable the condensate to flow in the pipes it is advisable to create an inclination of 1

cm

for every

2 meters of pipe in the direction of airflow. This condensate is collected in special containers positioned at

40/50-meter intervals. The outlet of the compressed air is above the collector and it is from here the inclination

starts. A condensate collector should be fitted at the end of the line.

2metres

condensation

collector

exhaust

valve

40-50metres

4

Fig. 7

Secondary network

.

The secondary network describes the series of vertical pipes connecting the primary network to the various “user

points” A condensate collector should be positioned at the end of each vertical line. On the secondary networks

one or more connection points are installed to enable the air out-take for the various users.